Schwarzbeck NSLK 8127 V-Line Impedance Stabilisation Network


Opt. RC: Option RC for LISN: Remote Control with built in power supply. LISN can be controlled by R&S or Schwarzbeck code, including remote control cable for your receiver type (Please specify your receiver type!). LISN can be selected from the R&S receiver menu or in the EMC32 software like an R&S LISN. No programming of the user interface necessary. Functions: path selection and PE grounded or via choke.

Opt. PLC: Option: Power Line Communication, according to EN 50065-1, selectable ranges: 3 – 9 kHz, 9 – 95 kHz, 95 kHz – 30 MHz, CISPR 16-1-2. Cannot be used in combination with other options.


Schwarzbeck NSLK 8127 V-Line Impedance Stabilisation Network
Richiedi Informazioni
Topology: V-LISN
Frequency Range: 9 kHz – 30 MHz
Pre-filter choke: 250 µH
Impedance simulation: 50 Ω || (50 µH + 5 Ω)
Max. Current: 2 x 16 A
Max. Voltage: 250 VAC 50/60 Hz
400 VDC
Supply cable: hard-wired three-wire connection cable with CEE 7/4 Type F (Schuko) plug
Connector for EuT: CEE 7/4 Type F (Schuko) socket
Connector for „artificial hand“: 4 mm laboratory socket with screw terminal 6 mm, not removable
Connector to EMI receiver: BNC socket 50 Ω
Lenght: 470 mm
Width: 445 mm
Height: 145 mm
Weight: 9.5 kg
Standard: CISPR 16-1-2